Skip to main content
Siemens 3VA1010-3ED42-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-3ED42-0KH0 MCCB, 100 A, 4-Pole, 75.6 kA at 2

MPN3VA1010-3ED42-0KH0

Siemens SENTRON 3VA1010-3ED42-0KH0, molded case circuit breaker, 4-pole, 100 A rated continuous current (Iu), TM210 thermal-magnetic release, shunt trip, interrupting rating 75.6 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1010-3ED42-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1010-3ED42-0KH0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1010-3ED42-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1010-3ED42-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1010-3ED42-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3

Environmental

3VA1010-3ED42-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1010-3ED42-0KH0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Line Protection MCCB with TM210 Release

The Siemens SENTRON 3VA1010-3ED42-0KH0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 100 A. The TM210 thermal-magnetic release provides overload and short-circuit protection without the complexity of an electronic trip — a straightforward choice for standard distribution panels where coordination studies are already done. Interrupting capacity is 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V — enough headroom for most low-voltage switchboards fed by a transformer in the 500–1000 kVA range. At 690 V the rating drops to 7.5 kA, so confirm the fault level if this breaker lands on a 690 V bus. The breaker includes a shunt trip release (STL) for remote opening, plus 2 auxiliary switches and 1 trip alarm switch (HQ configuration) — enough feedback for a PLC or status lamp without an add-on module. No undervoltage release, no ground-fault monitoring, no communication function: this is a pure power breaker, not a smart meter.

Thermal Derating and Panel Fit

Rated 100 A flat from 40 °C to 50 °C ambient; at 55 °C it derates to 96 A, at 60 °C to 94 A, at 65 °C to 92 A, and at 70 °C to 90 A. If the panel runs hot — say near a transformer or in a non-climate-controlled enclosure — size the upstream conductor and downstream bus for the derated value, not the nameplate 100 A. Dimensions: 101.6 mm wide, 130 mm high, 70 mm deep. The 101.6 mm width is a standard 4-pole MCCB footprint — it fits a 4-module cutout in most Siemens SENTRON distribution panels. Front IP40 rating means it's protected against tools and small wires but not against water ingress; keep it inside a cabinet. The integrated auxiliary trip is order code 3VA9688-0BL33 — that's the factory-fitted shunt trip coil. If you're replacing an existing breaker, verify the coil voltage matches your control circuit; the base breaker does not include a undervoltage release.

Frequently asked questions

Will 3VA1010-3ED42-0KH0 drop into a panel specified around 3VA1010-2ED32-0JA0?

Yes — same 101.6 mm width, same 4-pole footprint, same TM210 release. The difference is the shunt trip (STL) and the HQ auxiliary/alarm switch on the -3ED42-0KH0; the -2ED32-0JA0 lacks those. No rewiring needed for the power circuit.