Siemens 3VA1010-4ED32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-4ED32-0AA0-ZD00 Circuit Breaker, 100A, 36kA

MPN3VA1010-4ED32-0AA0-ZD00

Siemens 3VA1 IEC frame 100, breaking capacity class S, 3-pole, 100A, Icu=36kA @ 415V, line protection TM210, FTFM, fixed overload Ir=100A, fixed short-circuit Ii=10 x In, nut keeper kit for DC Power OEM in China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker is and what it does

The Siemens 3VA1010-4ED32-0AA0-ZD00 is a 3VA1 IEC frame 100 molded-case circuit breaker, 3-pole, rated In=100A with a breaking capacity class S delivering Icu=36kA at 415V. That 36kA interrupting rating means it can safely clear a fault up to that level without upstream cascading — critical for a main or feeder breaker in an industrial panel where available fault current is high. The TM210 thermal-magnetic trip unit gives fixed overload protection at Ir=100A and fixed short-circuit protection at Ii=10 x In (1000A). The FTFM designation indicates it's a fixed, non-interchangeable trip — what you order is what you get; no field trip-unit swaps.

What the ratings mean for fit

The fixed Ir=100A and Ii=10 x In (1000A magnetic pickup) suit this breaker for a feeder or large branch circuit where the load current is stable and known — a motor control center feeder, a distribution panel main, or a dedicated load like a 100A-rated compressor or pump. The 36kA @ 415V SCCR means it can be applied downstream of a transformer with substantial fault capacity without needing a current-limiting fuse ahead of it; verify the available fault current at the point of installation does not exceed 36kA. The 3-pole configuration covers three-phase systems. The nut keeper kit (included for the DC Power OEM variant) adds a mechanical anti-vibration feature for the line-side lugs — useful in high-vibration environments like near large contactors or drives.

Where this class is used

Molded-case circuit breakers in the 3VA1 frame (100A frame size) are standard in industrial control panels, switchboards, and motor control centers. They mount on DIN rail or bolt directly to a busbar system. The 3-pole design fits three-phase power distribution. The fixed trip means no field adjustment — specify the exact overload and short-circuit settings at order time, which this code does.

Frequently asked questions

Where can I buy 3VA1010-4ED32-0AA0-ZD00?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this breaker?

It has a breaking capacity class S with Icu=36kA at 415V, meaning it can safely interrupt fault currents up to 36kA at that voltage.

Does this breaker have a fixed or adjustable trip unit?

The TM210 trip unit is fixed (FTFM), with overload protection fixed at Ir=100A and short-circuit protection fixed at Ii=10 x In (1000A). No field adjustment is possible.