Skip to main content
Siemens 3VA1010-4ED32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-4ED32-0DC0 SENTRON MCCB, 100 A, 3-Pole, 121

MPN3VA1010-4ED32-0DC0

Siemens SENTRON 3VA1010-4ED32-0DC0, molded case circuit breaker, 3-pole, 100 A rated, 121 kA breaking capacity at 240 V AC, line protection design, undervoltage release included.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-4ED32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10104ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-4ED32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.27.5 W
3VA1010-4ED32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-4ED32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-4ED32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1010-4ED32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-4ED32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1010-4ED32-0DC0 — 100 A MCCB with Undervoltage Release

It is designed for line protection in distribution panels and switchboards, carrying a 121 kA interrupting rating at 240 V AC and 75.6 kA at 415 V AC.

This MCCB delivers 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. The high 121 kA figure at 240 V gives headroom for fault-current coordination downstream — useful when the upstream transformer or service entrance can deliver that level of prospective short-circuit current.

Thermal Derating and Continuous Current

At 55 °C it derates to 98 A, at 60 °C to 96 A, at 65 °C to 94 A, and at 70 °C to 91 A.

The 3-pole width (76.2 mm) is standard for a 100 A frame MCCB — it occupies three 25.4 mm pole spaces on a DIN rail or panel-mount footprint.

Listed as current production (active lifecycle stage). The 3VA1010-4ED32-0DC0 is a standard catalog item in the SENTRON 3VA series.

Frequently asked questions

How do I get current pricing and availability for 3VA1010-4ED32-0DC0?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is the breaking capacity of 3VA1010-4ED32-0DC0 at different voltages?

121 kA at 240 V AC, 75.6 kA at 415 V AC, 52.5 kA at 440 V AC, and 11.9 kA at both 500 V and 690 V AC.

Does 3VA1010-4ED32-0DC0 include an undervoltage release?

Yes, it is equipped with an undervoltage release (UVR) as standard, designated as an auxiliary release.

MPN