Skip to main content
Siemens 3VA1010-4ED32-0DH0 — Molded Case Circuit Breakers (MCCB)

3VA1010-4ED32-0DH0 SENTRON MCCB, 100 A, 3-pole, line protect

MPN3VA1010-4ED32-0DH0

Siemens SENTRON 3VA1010-4ED32-0DH0, molded case circuit breaker, 3-pole, 100 A, line protection with undervoltage release, 121 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-4ED32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10104ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1010-4ED32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.27.5 W
3VA1010-4ED32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-4ED32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-4ED32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1010-4ED32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-4ED32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection — 100 A frame with high interrupting capacity

The Siemens SENTRON 3VA1010-4ED32-0DH0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection, rated 100 A continuous at 40 °C ambient — no derating needed up to 50 °C where it still holds 100 A, then a gentle taper to 91 A at 70 °C. Interrupting capacity is the headline: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. That 121 kA at 240 V puts it comfortably above most utility transformer fault levels in North American panelboards — you get full selectivity without cascading upstream breakers.

Built-in undervoltage release and auxiliary switch complement

A trip indicator is present, so at-a-glance inspection confirms whether the breaker opened on overload/short or was manually switched off.

Frequently asked questions

Where can I buy 3VA1010-4ED32-0DH0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the interrupting capacity of 3VA1010-4ED32-0DH0 at 240 V?

121 kA at 240 V, with 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

What compliance documentation does this brand provide for 3VA1010-4ED32-0DH0?

As a Siemens SENTRON product, it carries UL, CSA, and IEC certifications standard for the series. RoHS and REACH compliance documentation is available from Siemens upon request.

MPN
3VA1010-4ED32-0DH0