Skip to main content
Siemens 3VA1010-4ED32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-4ED32-0JA0 SENTRON MCCB, 100 A, 3-Pole, 121

MPN3VA1010-4ED32-0JA0

Siemens SENTRON 3VA1010-4ED32-0JA0, molded case circuit breaker, 3-pole, 100 A rated continuous current Iu, TM210 overcurrent release, shunt trip (STL), breaking capacity 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, 11.9 kA at 690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1010-4ED32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1010-4ED32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA

Protection & Trip Unit

3VA1010-4ED32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1010-4ED32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1010-4ED32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1010-4ED32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1010-4ED32-0JA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this 100 A MCCB delivers on the line

The Siemens SENTRON 3VA1010-4ED32-0JA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current (Iu) at 40 °C through 50 °C, with a TM210 thermal-magnetic overcurrent release. Its interrupting capacity reaches 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V — figures that govern selectivity coordination downstream. The integrated shunt trip (STL) release (order code 3VA9688-0BL32 for the auxiliary trip unit) allows remote tripping via a control signal, so this breaker fits into a safety circuit that needs a hard-wired trip path independent of the overcurrent protection.

Sizing and thermal derating for panel builders

Rated continuous current holds at 100 A from 40 °C up to 50 °C ambient. Above that, derate linearly: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, 90 A at 70 °C. The TM210 release is fixed thermal-magnetic — no electronic adjustment, so the trip curve is set at the factory. Panel builders should confirm the 70 mm depth, 76.2 mm width, and 130 mm height clear the enclosure door and adjacent devices; IP40 on the front face means the breaker is protected against tools and solid objects larger than 1 mm, but not against water ingress — keep it inside a rated enclosure.

Key ratings at a glance

Rated insulation voltage Ui is 800 V. Mechanical endurance is rated at 15 000 cycles (latching endurance). The breaker includes a voltage trip trigger but no undervoltage release, no auxiliary contact version, no communication function, no phase failure detection, and no ground fault monitoring. Storage temperature range is -40 °C to 80 °C; operating ambient is -25 °C to 70 °C. Reference code per DIN EN 81346-2 is Q.

Frequently asked questions

How do I get current pricing and availability for 3VA1010-4ED32-0JA0?

Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the independent distribution channel; the part is sourced to order, not held on the shelf at a fixed price.

Will 3VA1010-4ED32-0JA0 drop into a panel specified around 3VA1010-4ED32-0AC0 without rewiring?

The -0JA0 variant includes a shunt trip (STL) release; the -0AC0 variant does not. The base breaker dimensions (70 mm depth, 76.2 mm width, 130 mm height) are identical, so the mechanical footprint and bus-bar positions are the same. Rewiring is only needed if the control circuit for the shunt trip is not already present in the panel.

What compliance documentation does this brand provide for 3VA1010-4ED32-0JA0?

Siemens SENTRON MCCBs typically carry RoHS, REACH, UL, and IEC compliance documentation. Request the specific declarations (CE, UKCA, EAC, UL listing) with your RFQ; the manufacturer provides them for active-production parts.

MPN
3VA1010-4ED32-0JA0