Skip to main content
Siemens 3VA1010-4ED36-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-4ED36-0AD0 SENTRON MCCB, 100 A, 3-Pole, 121

MPN3VA1010-4ED36-0AD0

Siemens SENTRON 3VA1010-4ED36-0AD0, molded case circuit breaker, 3-pole, 100 A rated continuous current, 121 kA at 240 V, TM210 release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-4ED36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-4ED36-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1010-4ED36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1010-4ED36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-4ED36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1010-4ED36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-4ED36-0AD0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

MCCB for panel builders — 100 A, 3-pole, high interrupting capacity

It carries 121 kA interrupting capacity at 240 V and 75.6 kA at 415 V, giving the panel designer headroom for high-fault installations.

The 100 A rating holds flat from 40 °C to 50 °C, then derates to 96 A at 55 °C and 90 A at 70 °C — useful for sealed enclosures or high-ambient machine compartments.

IP40 on the front face means it is suited for dry indoor panels; no washdown rating.

Frequently asked questions

Where can I buy 3VA1010-4ED36-0AD0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA1010-4ED36-0AD0 drop into a panel specified around 3VA1010-2ED42-0AE0 without rewiring?

Both are 3-pole 100 A SENTRON MCCBs on the same 76.2 mm wide frame, so the footprint and busbar spacing are identical. The difference is in the release and auxiliaries: this unit carries a TM210 thermal-magnetic release and three HQ auxiliary switches, whereas the sibling has a different release variant. Panel cutouts and wiring positions match, but verify the release curve and aux contact count against the original specification.

What is the interrupting capacity of this MCCB?

121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V — sufficient for high-fault industrial service entrances and distribution panels.

MPN
3VA1010-4ED36-0AD0