Skip to main content
Siemens 3VA1010-4ED36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-4ED36-0HC0 SENTRON MCCB, 100 A, 121 kA at 24

MPN3VA1010-4ED36-0HC0

Siemens SENTRON 3VA1010-4ED36-0HC0, 3-pole molded case circuit breaker, 100 A rated at 40 °C, 121 kA breaking capacity at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1010-4ED36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10104ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1010-4ED36-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.25 W

Protection & Trip Unit

3VA1010-4ED36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1010-4ED36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1010-4ED36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2

Environmental

3VA1010-4ED36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1010-4ED36-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1010-4ED36-0HC0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection. It carries a continuous current rating of 100 A at 40 °C, derating to 91 A at 70 °C — the full thermal curve is on the nameplate. Breaking capacity hits 121 kA at 240 V, stepping down to 75.6 kA at 415 V and 11.9 kA at 690 V, so it handles high-fault utility feeds without cascading upstream. Insulation voltage is rated 800 V, covering most 480/600 V industrial panels.

Footprint is 76.2 mm wide, 130 mm tall, 70 mm deep — fits standard 3-pole MCCB panel cutouts and DIN-rail adapter kits. Maximum power loss of 25 W means the enclosure needs to shed that heat; keep adjacent devices spaced per Siemens derating guidelines for ambient above 40 °C.

Built with a shunt trip release (STL) and two auxiliary switches HQ — the auxiliary switch design is integral, not a field-added kit. The basic switch assembly carries order code 3VA10104ED360AA0. No undervoltage release, no ground-fault monitoring, no communication function on this variant. Storage temperature range is -40 °C to 80 °C; operating range -25 °C to 70 °C.

Frequently asked questions

How do I get current pricing and availability for 3VA1010-4ED36-0HC0?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to confirm current pricing and availability at quote time.

What is the breaking capacity of 3VA1010-4ED36-0HC0 at 240 V?

The breaking capacity is 121 kA at 240 V.

Does 3VA1010-4ED36-0HC0 include a shunt trip?

Yes, it is equipped with a shunt trip release (STL) and two auxiliary switches HQ.

MPN
3VA1010-4ED36-0HC0