Siemens 3VA1010-4ED42-0BC0 SENTRON MCCB, 100A, 4-Pole, 121kA

MPN3VA1010-4ED42-0BC0

Siemens SENTRON 3VA1010-4ED42-0BC0, molded case circuit breaker, 4-pole, 100 A at 40 °C, breaking capacity 121 kA at 240 V AC, line protection design with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-4ED42-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10104ED420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-4ED42-0BC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.27.5 W
3VA1010-4ED42-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-4ED42-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-4ED42-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1010-4ED42-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-4ED42-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

It carries a continuous current of 100 A at 40 °C, holds that rating up through 50 °C, then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. That thermal curve means the breaker can sit in a warm panel without stepping down a frame size — useful when the enclosure runs hot from other gear. Breaking capacity is 121 kA at 240 V AC, dropping to 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. Power loss at full load runs 27.5 W maximum — factor that into the enclosure thermal budget.

Built-in undervoltage release

No ground-fault monitoring module is included; this is a straight line-protection MCCB with undervoltage and auxiliary signaling only.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

At 415 V AC the breaking capacity is 75.6 kA, which covers most industrial distribution panels fed from a medium-voltage transformer.

Does this breaker include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) and two auxiliary switches HQ as standard equipment.

Where can I buy 3VA1010-4ED42-0BC0 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock figures or price lists are published here.

MPN
3VA1010-4ED42-0BC0