Skip to main content
Siemens 3VA1020-2ED32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1020-2ED32-0AF0 SENTRON MCCB, 20A, 52.5kA at 240V

MPN3VA1020-2ED32-0AF0

Siemens SENTRON 3VA1020-2ED32-0AF0, 3-pole molded case circuit breaker, TM210 thermal-magnetic release, 20 A rated at 40 °C, 52.5 kA breaking capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1020-2ED32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10202ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1020-2ED32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.12 W
3VA1020-2ED32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1020-2ED32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1020-2ED32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1020-2ED32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1020-2ED32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It carries a TM210 thermal-magnetic release, rated 20 A at 40 °C with no derating needed up to 55 °C — at 60 °C it still holds 19 A, so it's stable across typical enclosure ambient conditions. Breaking capacity is 52.5 kA at 240 V AC, dropping to 32 kA at 415 V and 13.6 kA at 440 V — figures that place it solidly for North American 240/480 V distribution and IEC 415 V industrial mains. The breaker occupies a 76.2 mm (3 in) wide footprint on the DIN rail or panel mount, 130 mm tall, 70 mm deep. Maximum power loss is 12 W — modest for a 20 A frame, meaning less heat to vent inside a sealed enclosure.

Auxiliary switching and monitoring

Trip indicator is present, so a quick visual scan of the panel tells you which breaker opened.

Frequently asked questions

What auxiliary switches come fitted on this breaker?

One auxiliary switch plus one trip alarm switch (HQ type) are factory-installed — no separate accessory needed for status and fault indication.

Will 3VA1020-2ED32-0AF0 drop into a panel specified for 3VA1020-3ED36-0AA0?

Both are 3-pole SENTRON 3VA breakers sharing the same 76.2 mm width and 130 mm height, so the panel cutout and busbar spacing are identical. The difference is in the release — TM210 vs TM240 — so verify the trip curve matches your protection coordination.

MPN
3VA1020-2ED32-0AF0