Skip to main content
Siemens 3VA1020-2ED36-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1020-2ED36-0AF0 SENTRON MCCB, 20 A, 52.5 kA

MPN3VA1020-2ED36-0AF0

Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA1020-2ED36-0AF0, 3-pole, 20 A, line protection, TM210 thermal-magnetic release, breaking capacity 52.5 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1020-2ED36-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1020-2ED36-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C19.2 A
Current at 60 °C18.8 A
Current at 65 °C18.4 A
Current at 70 °C18 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1020-2ED36-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1020-2ED36-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1020-2ED36-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1020-2ED36-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1020-2ED36-0AF0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

It carries a breaking capacity of 52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — so it can clear high-fault currents on the secondary side of a distribution transformer or at a panel main without upstream coordination issues. The 20 A rating holds flat from 40 °C to 50 °C, then derates to 19.2 A at 55 °C and 18 A at 70 °C.

The IP40 front protection means it's splash-safe from the front in a typical enclosed panel; no outdoor or washdown rating. Mechanical endurance is 15,000 operations — that's a standard figure for a fixed-mounted MCCB in a distribution board where it cycles a few times a year, not a motor-starting duty cycle.

Frequently asked questions

What compliance documentation does this brand provide for 3VA1020-2ED36-0AF0?

Siemens SENTRON 3VA series MCCBs carry UL, CSA, and IEC certifications. RoHS and REACH declarations are standard with the product documentation package. Specific cert numbers are listed on the nameplate and in the device manual.

MPN