Siemens 3VA1020-3ED32-0AA0 SENTRON MCCB, 20A, 3-Pole, 75.6kA

MPN3VA1020-3ED32-0AA0
Active

Siemens SENTRON 3VA1020-3ED32-0AA0, molded case circuit breaker, 3-pole, 20 A, TM210 thermal-magnetic release, 75.6 kA at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1020-3ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1020-3ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.12 W
3VA1020-3ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1020-3ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1020-3ED32-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1020-3ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1020-3ED32-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1020-3ED32-0AA0 — 20 A MCCB with TM210 release

Breaking capacity across common system voltages

Breaking capacity is voltage-dependent: 75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

At 60 °C and 65 °C it derates to 19 A, and at 70 °C it remains at 19 A. This means the 20 A rating is maintained across typical panel ambient conditions — no derating needed unless the enclosure runs above 55 °C.

The 3-pole width (76.2 mm) is standard for this frame size — it fits the same DIN-rail or screw-mount footprint as other 3VA 3-pole units. No neutral conductor upgrade or motor drive option is fitted on this variant.

Frequently asked questions

What is the breaking capacity of 3VA1020-3ED32-0AA0 at 415 V?

At 415 V AC the breaking capacity is 52.5 kA.

Where can I buy 3VA1020-3ED32-0AA0?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm availability and pricing.

Does 3VA1020-3ED32-0AA0 include a neutral conductor or motor drive?

No — the neutral conductor is not upgradeable/retrofittable, and the motor drive option is not fitted on this variant.