Siemens 3VA1020-3ED32-0HC0 SENTRON MCCB, 20 A, 3-Pole, 75.6

MPN3VA1020-3ED32-0HC0

Siemens SENTRON 3VA1020-3ED32-0HC0, molded case circuit breaker, 3-pole, 20 A rated current, 75.6 kA breaking capacity at 240 V AC, line protection design, with shunt trip and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1020-3ED32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10203ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1020-3ED32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.12 W
3VA1020-3ED32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1020-3ED32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1020-3ED32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1020-3ED32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1020-3ED32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection — 20 A, 3-pole, with shunt trip

The Siemens SENTRON 3VA1020-3ED32-0HC0 is a 3-pole molded case circuit breaker (MCCB) rated for 20 A continuous current across the full ambient range from 40 °C to 55 °C, derating to 19 A at 60–70 °C. Breaking capacity reaches 75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 500 V and 690 V — covering most low-voltage distribution fault levels. This MCCB is configured for line protection (cable/feeder) and ships with a factory-installed shunt trip (STL) plus two HQ auxiliary switches.

The 70 mm depth (2.76 in) is shallow enough for most distribution enclosures; the 76.2 mm width (3 in) is the standard 3-pole MCCB footprint for this current class.

MPN