Skip to main content
Siemens 3VA1020-3ED32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1020-3ED32-0JC0 SENTRON MCCB, 20 A, 3-Pole, 75.6

MPN3VA1020-3ED32-0JC0

Siemens SENTRON 3VA1020-3ED32-0JC0, molded case circuit breaker, 3-pole, 20 A rated, breaking capacity 75.6 kA at 240 V, line protection design, with shunt trip and 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1020-3ED32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10203ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1020-3ED32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.12 W
3VA1020-3ED32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1020-3ED32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1020-3ED32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1020-3ED32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1020-3ED32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Line protection MCCB with shunt trip and auxiliary switches

The Siemens SENTRON 3VA1020-3ED32-0JC0 is a 3-pole molded case circuit breaker rated for 20 A continuous current across the ambient range from 40 °C to 70 °C, with only a 1 A derating at the top end (19 A at 60–70 °C). Its interrupting capacity scales with system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V — giving you headroom for high-fault panels in industrial distribution.

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep — a standard SENTRON 3VA footprint that fits existing DIN-rail or panel-mount cutouts for the 3VA family. The 3-pole body leaves room for side-mounted auxiliary switch blocks without crowding adjacent devices.

Frequently asked questions

Where can I buy 3VA1020-3ED32-0JC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1020-3ED32-0JC0 at 415 V?

The breaking capacity is 52.5 kA at 415 V, with higher ratings at lower voltages (75.6 kA at 240 V) and lower ratings at higher voltages (7.5 kA at 500 V and 690 V).

Does 3VA1020-3ED32-0JC0 include a shunt trip?

Yes, it is equipped with a shunt trip (STL) and two HQ auxiliary switches for remote tripping and status indication.

MPN
3VA1020-3ED32-0JC0