Siemens 3VA1025-2ED32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1025-2ED32-0CH0 SENTRON MCCB, 25 A, 52.5 kA at 24

MPN3VA1025-2ED32-0CH0

Siemens SENTRON 3VA1025-2ED32-0CH0, molded case circuit breaker (MCCB), 3-pole, 25 A rated continuous current (Iu), breaking capacity 52.5 kA at 240 V, TM210 thermal-magnetic release, with undervoltage release and 2 auxiliary + 1 alarm switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1025-2ED32-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1025-2ED32-0CH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C23.5 A
Current at 65 °C23 A
Current at 70 °C22.5 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1025-2ED32-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1025-2ED32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1025-2ED32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1025-2ED32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1025-2ED32-0CH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The front-face protection class is IP40, so it's suited for installation inside a dry enclosure where tools or fingers won't contact live parts.

Breaking capacity — what the voltages tell you

Breaking capacity varies sharply with system voltage: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V.

Built-in undervoltage release and auxiliary contacts

That's a standard requirement for safety circuits and machinery directives.

The 76.2 mm width (3 inches) is the standard 3-pole MCCB footprint for this current range — it fits the same panel cutout and busbar spacing as other SENTRON 3VA frames. Depth of 70 mm means it clears most standard enclosure depths without interference, but verify clearance for the undervoltage release wiring and auxiliary cable exit.

Frequently asked questions

Where can I buy 3VA1025-2ED32-0CH0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1025-2ED32-0CH0 at different voltages?

Breaking capacity is 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V.

Does 3VA1025-2ED32-0CH0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) as standard, plus 2 auxiliary switches and 1 trip alarm switch (HQ).