Siemens 3VA1025-3ED32-0CC0 SENTRON MCCB, 25 A, 3-pole

MPN3VA1025-3ED32-0CC0

Siemens SENTRON 3VA1025-3ED32-0CC0, 3-pole molded case circuit breaker, 25 A rated current at 40 °C, 75.6 kA breaking capacity at 240 V AC, with undervoltage release and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1025-3ED32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10253ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1025-3ED32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.11 W
3VA1025-3ED32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1025-3ED32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1025-3ED32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1025-3ED32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1025-3ED32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1025-3ED32-0CC0 is a 3-pole molded case circuit breaker (MCCB) rated 25 A at 40 °C, with a breaking capacity of 75.6 kA at 240 V AC. The thermal-magnetic trip curve is fixed for line protection — no communication module or ground-fault monitoring is fitted on this variant.

The interrupting rating drops with system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

Rated 25 A from 40 °C through 50 °C, then derates to 24 A at 55–60 °C and 23 A at 65–70 °C. If the panel ambient sits above 50 °C, plan for the 1–2 A reduction per the thermal curve.

Integrated auxiliary devices

The auxiliary switches provide remote status indication (open/closed) for the PLC or SCADA.

Width 76.2 mm (3 in), height 130 mm (5.12 in), depth 70 mm (2.76 in). The 3-pole footprint matches the SENTRON 3VA1 family panel cutout — no adapter plate needed for a 3VA1-based switchboard.

Frequently asked questions

What is the rated current of this MCCB at 40 °C?

The 3VA1025-3ED32-0CC0 is rated 25 A at 40 °C, and holds that rating through 50 °C before derating.

What breaking capacity does it have at 240 V and 415 V?

75.6 kA at 240 V AC and 52.5 kA at 415 V AC. At 690 V the interrupting rating is 7.5 kA.

Does this breaker include an undervoltage release?

Yes, it includes an undervoltage release (UVR) and two auxiliary switches (HQ design) for remote status indication.

How do I get current pricing and availability for this MCCB?