Skip to main content
Siemens 3VA1025-3ED32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1025-3ED32-0JA0 SENTRON MCCB, 25 A, 3-Pole, Shunt

MPN3VA1025-3ED32-0JA0

Siemens SENTRON 3VA1025-3ED32-0JA0, molded case circuit breaker, 3-pole, 25 A rated continuous current, TM210 thermal-magnetic release, shunt trip, line protection version, breaking capacity 75.6 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1025-3ED32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1025-3ED32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C23.5 A
Current at 65 °C23 A
Current at 70 °C22.5 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1025-3ED32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1025-3ED32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1025-3ED32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1025-3ED32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1025-3ED32-0JA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1025-3ED32-0JA0 is a SENTRON molded case circuit breaker (MCCB) rated for 25 A continuous current across a 40 °C to 50 °C ambient range, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) for remote tripping. Three poles, line protection version — no auxiliary contacts, no undervoltage release, no communication module. The 75.6 kA breaking capacity at 240 V drops to 52.5 kA at 415 V and 32 kA at 440 V; at 690 V it still clears 7.5 kA. That spread tells you this breaker is sized for 480 V or 600 V class distribution panels where the available fault current is known and the TM210 curve matches the downstream load.

Panel integration and footprint

Width 76.2 mm, height 130 mm, depth 70 mm — three-pole MCCB footprint that fits standard Siemens SENTRON mounting plates and busbar systems. No auxiliary contacts means no extra wiring space needed alongside. The shunt trip adds a pair of control wires; verify polarity on the release coil if your panel uses DC control.

Frequently asked questions

Where can I buy 3VA1025-3ED32-0JA0 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, not before.

What is the breaking capacity of this MCCB at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. The breaker clears faults across the full voltage range of a 480 V or 600 V distribution panel.

Does 3VA1025-3ED32-0JA0 include a shunt trip?

Yes, it has an integrated shunt trip (STL) for remote tripping. The release itself is a separate order code 3VA9688-0BL32 if you need a replacement.

MPN
3VA1025-3ED32-0JA0