Skip to main content
Siemens 3VA1025-3ED32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1025-3ED32-0KA0 SENTRON MCCB, 25A, 3-Pole, 75.6kA

MPN3VA1025-3ED32-0KA0

Siemens SENTRON 3VA1025-3ED32-0KA0, molded case circuit breaker, 3-pole, 25 A rated current at 40 °C, TM210 overcurrent release, shunt trip (STL), breaking capacity 75.6 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1025-3ED32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10253ED320AA0

Ratings

3VA1025-3ED32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.8.5 W

Protection & Trip Unit

3VA1025-3ED32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1025-3ED32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1025-3ED32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1025-3ED32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1025-3ED32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1025-3ED32-0KA0 is a SENTRON molded case circuit breaker (MCCB) sized for line protection in distribution panels. It carries a 25 A rated current at 40 °C, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) auxiliary release for remote tripping. Breaking capacity hits 75.6 kA at 240 V AC, stepping down to 52.5 kA at 415 V and 32 kA at 440 V — enough for most industrial fault-current scenarios on a 25 A feeder. Rated insulation voltage is 800 V, so it comfortably handles 480/600 V class systems.

Panel fit and integration

Three-pole frame, 76.2 mm wide, 130 mm tall, 70 mm deep. Mounts on a DIN rail or direct panel; the 70 mm depth keeps it clear of the gland plate on standard 200 mm deep enclosures. Power loss is 8.5 W maximum — negligible for thermal budgeting in a multi-breaker panel. No communication module, no ground-fault monitoring, no undervoltage release on this variant. The shunt trip (STL) is the only auxiliary release; if you need UVR or a separate alarm contact, order a different suffix.

Thermal derating and ambient limits

Rated current holds at 25 A from 40 °C through 50 °C ambient. At 55 °C it derates to 24 A, and at 70 °C to 23 A. Operating range is -25 °C to +70 °C; storage range extends from -40 °C to +80 °C.

Frequently asked questions

Where can I buy 3VA1025-3ED32-0KA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1025-3ED32-0KA0 at 240 V?

The breaking capacity is 75.6 kA at 240 V AC, with 52.5 kA at 415 V and 32 kA at 440 V.

What overcurrent release does this MCCB use?

It uses a TM210 thermal-magnetic overcurrent release — a fixed-trip design with thermal and magnetic elements for overload and short-circuit protection.

Does 3VA1025-3ED32-0KA0 include a shunt trip?

Yes, it includes a shunt trip (STL) auxiliary release for remote tripping. There is no undervoltage release on this variant.

MPN
3VA1025-3ED32-0KA0