Skip to main content
Siemens 3VA1025-4ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1025-4ED32-0AA0 SENTRON MCCB, 25 A, 3-Pole, TM210

MPN3VA1025-4ED32-0AA0
Active

Siemens SENTRON 3VA1025-4ED32-0AA0, molded case circuit breaker, 3-pole, 25 A, TM210 thermal-magnetic release, line protection, 121 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1025-4ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1025-4ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.8.5 W
3VA1025-4ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1025-4ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1025-4ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1025-4ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1025-4ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It carries a rated continuous current of 25 A across ambient temperatures from 40 °C to 50 °C, derating to 24 A at 55 °C and 60 °C, and 23 A at 65 °C and 70 °C — so you can count on full 25 A up to 50 °C before you need to account for thermal derating in a warm enclosure. The interrupting ratings are what make this part stand out: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

Overcurrent release and protection design

The "210" designates the specific trip curve family. If you need those add-ons, you'd look at a different variant in the 3VA family.

That 76.2 mm width (3 inches) is a standard 3-pole MCCB footprint for this current class — it will drop into a panel designed for a 3-pole SENTRON 3VA frame without needing to re-drill the mounting plate or adjust busbar spacing. Maximum power loss is 8.5 W — useful to know for thermal calculations inside a sealed enclosure.

For DC network applications, the evidence notes that switching power values in DC networks require consulting the 3VA molded case circuit breaker device manual — the standard AC ratings don't directly apply to DC circuits.