Skip to main content
Siemens 3VA1025-4ED32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1025-4ED32-0BH0 MCCB, 25A, 121kA at 240V

MPN3VA1025-4ED32-0BH0

Siemens SENTRON 3VA1025-4ED32-0BH0, molded case circuit breaker, 3-pole, 25 A rated current at 40 °C, 121 kA breaking capacity at 240 V AC, undervoltage release, 2 aux + 1 trip alarm switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1025-4ED32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10254ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1025-4ED32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.11 W
3VA1025-4ED32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1025-4ED32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1025-4ED32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1025-4ED32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1025-4ED32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection — 25 A, high interrupting capacity

The Siemens SENTRON 3VA1025-4ED32-0BH0 is a three-pole molded case circuit breaker (MCCB) rated for line protection at 25 A continuous, with no derating needed up to 50 °C — at 55 °C it holds 24 A, and at 70 °C it still carries 23 A. That thermal stability matters in a sealed or poorly vented panel where ambient climbs above 40 °C; you don't lose a full 20 % of capacity like some breakers do. Breaking capacity hits 121 kA at 240 V, drops to 75.6 kA at 415 V, and still holds 11.9 kA at 690 V — that puts it in the high-interrupting range for a 25 A frame, giving selectivity headroom downstream without cascading upstream breakers. The UVR drops the breaker when control voltage falls below a threshold — common for emergency-stop circuits or to prevent auto-reclose after a power dip. No ground-fault monitoring on this version; that's separate.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without needing adapter plates.

Frequently asked questions

Where can I buy 3VA1025-4ED32-0BH0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1025-4ED32-0BH0 at 240 V?

121 kA at 240 V AC. That's a high-interrupting rating for a 25 A frame, suitable for high-fault locations near transformers or large motor banks.

Does 3VA1025-4ED32-0BH0 include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) as the auxiliary release, plus two auxiliary switches and one trip alarm switch (HQ). No ground-fault monitoring is included.

MPN
3VA1025-4ED32-0BH0