Siemens 3VA1032-2ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1032-2ED32-0AA0 MCCB, 32 A, 52.5 kA at 24

MPN3VA1032-2ED32-0AA0
Active

Siemens SENTRON 3VA1032-2ED32-0AA0, molded case circuit breaker, 3-pole, 32 A rated continuous current, 52.5 kA breaking capacity at 240 V, TM210 overcurrent release, line protection design.

$81.28Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1032-2ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1032-2ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.10.6 W
3VA1032-2ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-2ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1032-2ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1032-2ED32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 32 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release. Breaking capacity is 52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500/690 V — enough for most industrial fault levels up to 240 V, but verify coordination at higher voltages where the interrupting rating drops. The insulation voltage is rated 800 V, so the breaker can be used in 480/277 V or 600 V systems as long as the available fault current stays under the 7.5 kA threshold at 500 V and above.

The breaker occupies a 76.2 mm wide by 130 mm tall by 70 mm deep footprint — standard for a 3-pole SENTRON 3VA frame. The 70 mm depth leaves clearance for rear-connected busbars or cable ladders in a typical 600 mm deep enclosure.

Frequently asked questions

Where can I buy 3VA1032-2ED32-0AA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is 3VA1032-2ED32-0AA0's listed depth (70 mm) on this component line?

The depth is 70 mm (2.76 in). That measurement includes the front-mounted handle and terminal covers; panel depth allowance should account for rear cable bending radius.

What is 3VA1032-2ED32-0AA0's listed width (76.2 mm) on this component line?

The width is 76.2 mm (3 in), which is the standard 3-pole MCCB width for the SENTRON 3VA frame. It fits a standard DIN-rail or panel cutout for that pole count.

Will 3VA1032-2ED32-0AA0 drop into a panel that was specified around 3VA1110-5ED32-0AA0 without rewiring?

The 3VA1032-2ED32-0AA0 and 3VA1110-5ED32-0AA0 share the same 3-pole SENTRON 3VA frame dimensions (76.2 mm wide, 130 mm tall, 70 mm deep), so physical fit in the panel is identical. However, the 3VA1110 variant carries a different overcurrent release and possibly a higher interrupting rating — verify the trip curve and SCCR coordination before swapping without rewiring.

MPN
3VA1032-2ED32-0AA0