Specifications

3VA1032-2ED32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10322ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1032-2ED32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.10.6 W
3VA1032-2ED32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-2ED32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1032-2ED32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The TM210 thermal-magnetic release handles overloads and short-circuits without an electronic trip unit — no auxiliary power needed, no communication function. That keeps the wiring simple and the failure mode predictable.

Breaking capacity varies by system voltage: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V. At 415 V the 32 kA rating covers most industrial transformer-fed panels. At 690 V the 7.5 kA figure is lower — verify the available fault current if feeding from a high-impedance source or a large transformer.

Fit and panel integration

Width is 76.2 mm (3 in), depth 70 mm (2.76 in), height 130 mm (5.12 in) — standard SENTRON 3VA1 footprint. The 70 mm depth leaves clearance behind most enclosure gland plates.

Frequently asked questions

What does the TM210 release mean?

TM210 is a thermal-magnetic overcurrent release — fixed thermal pickup at 32 A, magnetic short-circuit trip coordinated to the breaker's interrupting rating. No electronic trip unit, no adjustment dials.