Siemens 3VA1032-2ED32-0BA0 SENTRON MCCB, 32 A, 3-Pole, 52.5

MPN3VA1032-2ED32-0BA0

Siemens SENTRON 3VA1032-2ED32-0BA0, 3-pole molded case circuit breaker, 32 A rated continuous current, TM210 thermal-magnetic release, 52.5 kA breaking capacity at 240 V, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-2ED32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1032-2ED32-0BA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C30.72 A
Current at 60 °C30.08 A
Current at 65 °C29.44 A
Current at 70 °C28.8 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1032-2ED32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1032-2ED32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1032-2ED32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED32-0BA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1032-2ED32-0BA0 is a SENTRON 3-pole molded case circuit breaker (MCCB) rated for 32 A continuous current at 40 °C, with a TM210 thermal-magnetic release. It carries a 52.5 kA interrupting capacity at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — the breaking curve you need to match against the available fault current at the panelboard.

An undervoltage release (UVR) is fitted as standard, so verify your control voltage matches the release coil rating before energizing.

Derating is minimal up to 50 °C — still 32 A. At 55 °C it drops to 30.72 A, at 60 °C to 30.08 A, at 65 °C to 29.44 A, and at 70 °C to 28.8 A.

Frequently asked questions

Where can I buy 3VA1032-2ED32-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the closest functional alternative to 3VA1032-2ED32-0BA0?

The 3VA1010-2ED42-0AE0 is a sibling in the same SENTRON 3VA family, but it carries a 10 A frame rating versus the 32 A of this part. They share the same 3-pole form factor and TM release architecture, so a panel laid out for one can accept the other without rewiring — provided the load current and interrupting capacity requirements match the alternative's ratings.

What compliance documentation does this breaker carry?

The SENTRON 3VA series is designed to meet IEC 60947-2 and UL 489 standards for molded case circuit breakers. Specific RoHS, REACH, and CE declarations are available from Siemens documentation for this order code.