Skip to main content
Siemens 3VA1032-2ED32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-2ED32-0DA0 SENTRON MCCB, 32A, 52.5kA at 240V

MPN3VA1032-2ED32-0DA0

Siemens SENTRON 3VA1032-2ED32-0DA0, 3-pole molded case circuit breaker, 32 A rated at 40 °C, breaking capacity 52.5 kA at 240 V, undervoltage release, TM210 overcurrent release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-2ED32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10322ED320AA0
3VA1032-2ED32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.13.1 W
3VA1032-2ED32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-2ED32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1032-2ED32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The 3VA1032-2ED32-0DA0: At 415 V this MCCB interrupts 32 kA, and at 440 V it's still 13.6 kA. Power loss is 13.1 W maximum — modest for a 32 A frame, so adjacent devices in a crowded enclosure won't see excessive heat soak. The TM210 release is fixed thermal-magnetic; no electronic adjustment, but for a straight feeder or non-critical motor branch that's fine.

Footprint is 76.2 mm wide by 130 mm tall by 70 mm deep — standard SENTRON 3VA1 frame size. Bolts onto a backplate or mounts on a DIN rail adapter. The UVR coil takes up a bit of internal space but doesn't change the external dimensions. If you're swapping into a panel cut for a 3VA1, this drops in without re-drilling.

Frequently asked questions

What is the breaking capacity of 3VA1032-2ED32-0DA0 at 415 V?

32 kA at 415 V, and 52.5 kA at 240 V.

Does 3VA1032-2ED32-0DA0 include an undervoltage release?

Yes, it is designed with an undervoltage release (UVR) as the auxiliary release.

Where can I buy 3VA1032-2ED32-0DA0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
3VA1032-2ED32-0DA0