Skip to main content
Siemens 3VA1032-2ED36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-2ED36-0AC0 SENTRON MCCB, 32 A, 52.5 kA

MPN3VA1032-2ED36-0AC0

Siemens SENTRON 3VA1032-2ED36-0AC0, 3-pole molded case circuit breaker, 32 A (40 °C), 52.5 kA at 240 V, TM210 thermal-magnetic release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-2ED36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10322ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1032-2ED36-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.10.6 W
3VA1032-2ED36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-2ED36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1032-2ED36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED36-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1 MCCB for line protection

It carries a TM210 thermal-magnetic release — the thermal element handles overloads, the magnetic element clears short-circuits — and is rated 32 A continuously at 40 °C ambient, derating to 30 A at 70 °C. That 32 A rating holds all the way to 50 °C, so it keeps full capacity in a warm enclosure without oversizing. Breaking capacity is 52.5 kA at 240 V AC, dropping to 32 kA at 415 V and 13.6 kA at 440 V — enough for most industrial service-entrance or sub-distribution boards where fault current runs high at lower voltages. The 3VA1 frame is a compact 3-inch-wide (76.2 mm) footprint that fits standard panel cutouts. Depth is 70 mm, height 130 mm.

That keeps it simple and reliable for line protection where you want a predictable trip curve without programming. For selectivity studies: the 52.5 kA at 240 V and 32 kA at 415 V give good discrimination with downstream 10 kA or 18 kA rated breakers, as long as the cascading ratio stays within typical 2:1 guidelines.

Frequently asked questions

Who supplies 3VA1032-2ED36-0AC0 and how is it quoted?

Sourced through independent industrial-automation distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here, but the supply chain is active for this current-production part.

What is the breaking capacity of 3VA1032-2ED36-0AC0 at different voltages?

Breaking capacity is 52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The high 52.5 kA figure at 240 V suits service-entrance or high-fault sub-distribution applications.

What is the rated current of 3VA1032-2ED36-0AC0 at elevated ambient temperatures?

Rated 32 A continuously from 40 °C through 50 °C, then derates to 31 A at 55 °C and 60 °C, and 30 A at 65 °C and 70 °C. No derating needed up to 50 °C, which covers most enclosed panel ambients.

Will 3VA1032-2ED36-0AC0 drop into a panel specified for 3VA1110-5ED36-0AC0 without rewiring?

Both are 3-pole SENTRON 3VA1 frame MCCBs with the same 76.2 mm width and 70 mm depth, so they share the same panel cutout and bus-bar spacing. However, the 3VA1110-5ED36-0AC0 is a higher-current variant (typically 100 A frame) with different lug sizes and a different release — verify lug wire range and thermal-magnetic curve before substituting. Mechanical fit is the same; electrical fit depends on load current and coordination study.

MPN
3VA1032-2ED36-0AC0