Skip to main content
Siemens 3VA1032-2ED36-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-2ED36-0AD0 SENTRON MCCB, 32 A, 52.5 kA at 24

MPN3VA1032-2ED36-0AD0

Siemens SENTRON series, molded case circuit breaker (MCCB), 3VA1032-2ED36-0AD0, 3-pole, 32 A rated current, TM210 thermal-magnetic release, breaking capacity 52.5 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-2ED36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10322ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1032-2ED36-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.10.6 W
3VA1032-2ED36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-2ED36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1032-2ED36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED36-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1032-2ED36-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated for 32 A at 40 °C, with a TM210 thermal-magnetic release designed for line protection — meaning it handles overloads and short circuits in distribution panels, motor control centers, or as a main feeder breaker. The 52.5 kA breaking capacity at 240 V gives you headroom on high-fault utility feeds, and it still interrupts 32 kA at 415 V and 13.6 kA at 440 V, so it holds up on 480 V delta systems common in North American plants.

This MCCB's interrupting rating drops as system voltage rises: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The three-pole construction switches all phases simultaneously, so it's suitable for three-phase feeders and motor branch circuits.

Sizing and thermal performance across temperature

The breaker holds its full 32 A rating from 40 °C through 50 °C, then derates to 31 A at 55 °C and 60 °C, and 30 A at 65 °C and 70 °C.

The 3VA1032-2ED36-0AD0 measures 130 mm tall, 76.2 mm wide, and 70 mm deep. Width of 76.2 mm (3 inches) is standard for a 3-pole 32 A MCCB — it occupies three 25 mm DIN spaces if mounted on a rail, or bolts directly to a backplate. No undervoltage release or shunt trip is built in (the listing shows no voltage trigger and no undervoltage release), so if you need remote trip, you'll add an external accessory.

Frequently asked questions

What is the breaking capacity of 3VA1032-2ED36-0AD0 at 240 V?

The interrupting rating is 52.5 kA at 240 V. It also carries 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V.

Where can I buy the 3VA1032-2ED36-0AD0 and get current pricing?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — figures are confirmed at quote time.

What is the width of 3VA1032-2ED36-0AD0?

The width is 76.2 mm (3 inches), which is standard for a 3-pole MCCB in this frame size.

Does the 3VA1032-2ED36-0AD0 have a shunt trip or undervoltage release?

No. The listing shows no voltage trigger and no undervoltage release. If remote tripping is needed, an external accessory must be added.

MPN
3VA1032-2ED36-0AD0