Skip to main content
Siemens 3VA1032-2ED36-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-2ED36-0CC0 SENTRON MCCB, 32 A, 3-Pole, 52.5

MPN3VA1032-2ED36-0CC0

Siemens SENTRON 3VA1032-2ED36-0CC0, molded case circuit breaker, 3-pole, 32 A rated continuous current, 52.5 kA interrupting at 240 V, TM210 release, undervoltage release, 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-2ED36-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1032-2ED36-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C30.72 A
Current at 60 °C30.08 A
Current at 65 °C29.44 A
Current at 70 °C28.8 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1032-2ED36-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1032-2ED36-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED36-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1032-2ED36-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED36-0CC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Its interrupting capacity hits 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — so it handles high-fault utility feeds or transformer secondaries where the available fault current is substantial. The UVR lets you trip the breaker on loss of control voltage — useful for safety circuits or remote shutdown schemes. Front face carries IP40 protection — fine for enclosed switchgear, not for washdown areas.

Above that it steps down: 30.72 A at 55 °C, 30.08 A at 60 °C, 29.44 A at 65 °C, and 28.8 A at 70 °C.

Frequently asked questions

Where can I buy 3VA1032-2ED36-0CC0 and get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, no stock figures listed here.

What is the interrupting capacity of this MCCB at 415 V?

32 kA at 415 V. It also carries 52.5 kA at 240 V, 13.6 kA at 440 V, and 7.5 kA at 690 V.

Does this breaker include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) and two high-quality auxiliary switches. The UVR trips the breaker when control voltage drops, which is typical for emergency-stop or safety circuits.

Will 3VA1032-2ED36-0CC0 drop into a panel specified for 3VA1010-2ED42-0AE0?

Both are 3-pole SENTRON MCCBs in the same physical frame family, so the mounting footprint and bus connections are shared. The key difference is the continuous current rating and interrupting capacity — verify your load and fault-current requirements against the 32 A / 52.5 kA spec of this unit before swapping.

MPN
3VA1032-2ED36-0CC0