Skip to main content
Siemens 3VA1032-2ED36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-2ED36-0HC0 SENTRON MCCB, 32 A, 52.5 kA at 24

MPN3VA1032-2ED36-0HC0

Siemens SENTRON 3VA1032-2ED36-0HC0, molded case circuit breaker, 3-pole, 32 A rated continuous current Iu, 52.5 kA breaking capacity at 240 V AC, line protection version with TM210 thermal-magnetic release, IP40 front protection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1032-2ED36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1032-2ED36-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C30.72 A
Current at 60 °C30.08 A
Current at 65 °C29.44 A
Current at 70 °C28.8 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1032-2ED36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1032-2ED36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1032-2ED36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2

Environmental

3VA1032-2ED36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1032-2ED36-0HC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens SENTRON 3VA1032-2ED36-0HC0 — 32 A MCCB with TM210 Release

The Siemens 3VA1032-2ED36-0HC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 32 A continuous current (Iu) with an 800 V rated insulation voltage (Ui). It carries a TM210 thermal-magnetic overcurrent release, meaning the thermal element handles overloads and the magnetic element handles short-circuits — no electronic adjustment, just a fixed curve that's predictable for panel coordination. Breaking capacity steps: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. That 52.5 kA figure at 240 V gives you headroom on most North American 240/120 V distribution panels; the 32 kA at 415 V covers the common European 400 V three-phase grid. The 7.5 kA at 690 V is enough for most 690 V industrial drives but not for high-fault utility tie points — check your available fault current before specifying. Derating is tight up to 50 °C — the breaker holds its full 32 A rating at 40 °C, 45 °C, and 50 °C. At 55 °C it drops to 30.72 A, at 60 °C to 30.08 A, at 65 °C to 29.44 A, and at 70 °C to 28.8 A. If your panel ambient runs above 50 °C, you lose about 0.64 A per 5 °C step. Plan your continuous load accordingly.

Fit and Integration — Panel Space and Wiring

The 3VA1032-2ED36-0HC0 measures 130 mm high, 76.2 mm wide, and 70 mm deep. That 76.2 mm width is a standard 3-pole MCCB footprint — it fits the same DIN-rail or panel-mount cutout as other SENTRON 3VA frame breakers. No surprises if you're swapping in from a 3VA10 or 3VA11 frame. IP40 on the front means it's protected against tools and wires over 1 mm, but not against water ingress. Fine for a dry indoor panel; don't put it in a washdown zone without an enclosure. Comes with 2 auxiliary switches (HQ type) and a shunt trip release (STL) — the shunt trip is ordered separately as 3VA9688-0BL30. If your safety circuit needs an undervoltage release, this variant doesn't carry one; you'd need a different order code. No communication module or phase-failure detection on this version.

Frequently asked questions

Where can I buy 3VA1032-2ED36-0HC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What are the key ratings for this MCCB?

Rated continuous current Iu is 32 A, with an 800 V rated insulation voltage Ui. Breaking capacity is 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. The overcurrent release is a TM210 thermal-magnetic type.

What is the depth of the 3VA1032-2ED36-0HC0?

The depth is 70 mm. Overall dimensions are 130 mm high by 76.2 mm wide by 70 mm deep.

Does this breaker include a shunt trip or undervoltage release?

It includes a shunt trip release (STL) ordered as accessory 3VA9688-0BL30. It does not include an undervoltage release.

MPN
3VA1032-2ED36-0HC0