Siemens 3VA1032-2ED42-0AA0-ZD00 Circuit Breaker, 32A, 16kA @

MPN3VA1032-2ED42-0AA0-ZD00

Siemens 3VA1 IEC frame 100 circuit breaker, 4-pole, 32 A, breaking capacity class B Icu=16 kA @ 415 V, TM210 line protection, fixed thermal and short-circuit settings, N conductor unprotected, nut keeper kit, DC Power OEM variant for China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this 3VA1 breaker is and what the ratings mean for fit

The Siemens 3VA1032-2ED42-0AA0-ZD00 is a 4-pole IEC frame 100 circuit breaker rated 32 A, with a breaking capacity of 16 kA at 415 V (class B). That 16 kA Icu tells you it can safely interrupt a fault current up to that level at 415 V without failing — critical for verifying the available fault current at the panel's main distribution point doesn't exceed this rating. The TM210 release provides fixed thermal overload protection set at Ir = 32 A and fixed short-circuit protection at Ii = 10 × In (320 A). This variant is configured for line protection with the N conductor left unprotected, and includes a nut keeper kit. The suffix ZD00 flags it as a DC Power OEM variant destined for the China market — the same core breaker platform, but with a specific accessory and documentation package for that supply chain.

Panel integration notes

Mounts on DIN rail in the standard enclosure. The 4-pole footprint occupies four module widths; plan the gland plate and busbar routing accordingly. The nut keeper kit secures the breaker against vibration in OEM builds — verify the torque spec on the terminal screws during panel assembly.

Frequently asked questions

Where can I buy 3VA1032-2ED42-0AA0-ZD00 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this breaker?

The breaking capacity is Icu = 16 kA at 415 V (class B per IEC 60947-2), meaning it can safely interrupt fault currents up to that level at 415 V without damage to the breaker or downstream equipment.

What does the TM210 release mean for protection settings?

The TM210 provides fixed thermal overload protection at Ir = 32 A and fixed short-circuit protection at Ii = 10 × In (320 A). These are not adjustable — the breaker is factory-set for these thresholds, so verify they match your load's inrush and continuous current requirements before specifying.