Siemens 3VA1032-3ED32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-3ED32-0DA0 SENTRON MCCB, 32 A, 3-Pole, TM210

MPN3VA1032-3ED32-0DA0

Siemens SENTRON 3VA1032-3ED32-0DA0, 3-pole molded case circuit breaker, 32 A (40 °C), TM210 trip, line protection, 70 x 76.2 x 130 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-3ED32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10323ED320AA0
3VA1032-3ED32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.13.1 W
3VA1032-3ED32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-3ED32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-3ED32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1032-3ED32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-3ED32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The 3VA1032-3ED32-0DA0: At 240 V it interrupts 75.6 kA, at 415 V it's 52.5 kA, and at 440 V it drops to 32 kA. That 75.6 kA at 240 V gives you serious fault-current headroom for a 32 A frame — useful if you're feeding a sub-panel with a high-capacity transformer upstream and need selectivity with a downstream 32 A breaker.

Thermal derating and the TM210 trip

The TM210 thermal-magnetic trip holds 32 A from 40 °C up to 50 °C, then derates to 31 A at 55 °C and 60 °C, and 30 A at 65 °C and 70 °C.

Built-in undervoltage release

That means if your control voltage dips below the dropout threshold, the breaker trips automatically. No need to add a separate shunt trip module or wire an external relay for undervoltage protection. The UVR is factory-integrated, so verify your control voltage matches the release rating before wiring.

No need to re-drill the sub-panel or re-lay bus bars if you're swapping from a different 3VA variant.

Frequently asked questions

Where can I buy 3VA1032-3ED32-0DA0 and get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, not from a static listing.

What is the breaking capacity of 3VA1032-3ED32-0DA0 at 240 V?

It interrupts 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

Does 3VA1032-3ED32-0DA0 include an undervoltage release?

Yes, it ships with a factory-integrated undervoltage release (UVR) as the auxiliary release — no separate shunt trip module needed.

MPN
3VA1032-3ED32-0DA0