Skip to main content
Siemens 3VA1032-3ED36-0AD0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1032-3ED36-0AD0 MCCB, 32 A, 3-Pole, 75.6 kA at 24

MPN3VA1032-3ED36-0AD0

Siemens SENTRON 3VA1032-3ED36-0AD0, molded case circuit breaker, 3-pole, 32 A (40 °C), TM210 thermal-magnetic release, breaking capacity 75.6 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-3ED36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10323ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1032-3ED36-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.10.6 W
3VA1032-3ED36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-3ED36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-3ED36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1032-3ED36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-3ED36-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1032-3ED36-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated 32 A at 40 °C, fitted with a TM210 thermal-magnetic overcurrent release. Breaking capacity runs 75.6 kA at 240 V AC, 52.5 kA at 415 V, and still holds 7.5 kA at 690 V, so it handles high-fault utility feeds without cascading upstream.

The 32 A rating holds flat from 40 °C to 50 °C, then derates to 31 A at 55 °C and 30 A at 70 °C — that's a clean thermal curve for a warm panel. Power loss maxes at 10.6 W, which matters when you're stacking breakers in a multi-panel lineup and calculating heat rise. The 70 mm depth and 76.2 mm width (3 inches) are standard SENTRON 3VA footprint — it drops into the same panel cutouts and bus connections as other 3VA frame sizes.

Frequently asked questions

Where can I buy 3VA1032-3ED36-0AD0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1032-3ED36-0AD0 at different voltages?

75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V. That covers most industrial service entrances and distribution feeders.

MPN
3VA1032-3ED36-0AD0