Skip to main content
Siemens 3VA1032-3ED36-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-3ED36-0BH0 SENTRON MCCB, 32 A, 3-pole, 75.6

MPN3VA1032-3ED36-0BH0

Siemens SENTRON 3VA1032-3ED36-0BH0, molded case circuit breaker, 3-pole, 32 A at 40 °C, interrupting 75.6 kA at 240 V, line protection design, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-3ED36-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10323ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1032-3ED36-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.13.1 W
3VA1032-3ED36-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1032-3ED36-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-3ED36-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1032-3ED36-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-3ED36-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection — 32 A, 75.6 kA interrupting

It carries 32 A continuously at 40 °C ambient (derated to 30 A at 70 °C) and interrupts fault currents up to 75.6 kA at 240 V AC — enough to clear high-energy faults on a 240 V bus without upstream coordination failure. The supplied basic switch is 3VA10323ED360AA0.

The 3VA1032-3ED36-0BH0 measures 130 mm high by 76.2 mm wide by 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or screw-mount panel layouts. The 70 mm depth keeps the breaker within a 200 mm enclosure depth without crowding gland plates or busbars.

Frequently asked questions

What are the interrupting ratings for 3VA1032-3ED36-0BH0?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 500 V and 690 V.

Where can I buy 3VA1032-3ED36-0BH0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the depth of 3VA1032-3ED36-0BH0?

70 mm (2.76 in).

MPN