Siemens 3VA1032-3ED36-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-3ED36-0DC0 SENTRON MCCB, 32A, 3-Pole, 75.6kA

MPN3VA1032-3ED36-0DC0

Siemens SENTRON 3VA1032-3ED36-0DC0, 3-pole molded case circuit breaker, 32 A, line protection, with undervoltage release and 2 HQ auxiliary switches, breaking capacity 75.6 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1032-3ED36-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10323ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1032-3ED36-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.13.1 W

Protection & Trip Unit

3VA1032-3ED36-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1032-3ED36-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1032-3ED36-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2

Environmental

3VA1032-3ED36-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1032-3ED36-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1032-3ED36-0DC0 — MCCB for line protection in active production

The Siemens 3VA1032-3ED36-0DC0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. It carries a continuous current rating of 32 A across the 40 °C to 50 °C ambient range, derating to 30 A at 70 °C — a curve that matters when you're packing breakers into a hot enclosure near a mill drive or furnace zone. Three-pole construction, rated insulation voltage of 800 V, and interrupting capacity that steps from 75.6 kA at 240 V down to 7.5 kA at 690 V. That 75.6 kA at 240 V gives you headroom for high-fault service-entrance applications; the 7.5 kA at 690 V still clears most industrial feeder faults where the upstream transformer impedance limits through-fault current. This unit ships with an integrated undervoltage release (UVR) and two HQ auxiliary switches — no separate add-on kit to source. The UVR drops the breaker on loss of control voltage, which is standard practice for emergency-stop circuits and safety isolation in conveyor or press lines.

Thermal performance and panel integration

Dimensions: 130 mm height, 76.2 mm width, 70 mm depth. Fits a standard 3-pole MCCB footprint on DIN rail or direct panel mount. The 70 mm depth leaves room for wiring gutters in a 200 mm deep enclosure — no need to oversize the cabinet for this breaker. Power loss is 13.1 W maximum at rated current. In a multi-breaker panel, that's low enough to avoid forced ventilation in most indoor installations, but if you're grouping six or more breakers at full load in a sealed enclosure, add a vent or derate per the manufacturer's grouping factor. Operating temperature range -25 °C to 70 °C; storage from -40 °C to 80 °C. The storage floor matters for winter-site commissioning — the breaker can sit in an unheated warehouse and still start up when the panel is energized.

Frequently asked questions

What is the breaking capacity of 3VA1032-3ED36-0DC0 at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The interrupting rating declines with system voltage, so verify the available fault current at your operating voltage.

Does 3VA1032-3ED36-0DC0 include an undervoltage release?

Yes, it ships with an integrated undervoltage release (UVR) and two HQ auxiliary switches. No separate accessory purchase is needed for undervoltage protection.

Where can I buy 3VA1032-3ED36-0DC0 and how is it quoted?

This part is sourced to order through independent industrial distribution. Submit an RFQ for current pricing and availability — a firm quote is provided at the time of request.

MPN
3VA1032-3ED36-0DC0