Skip to main content
Siemens 3VA1032-4ED36-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-4ED36-0KA0 SENTRON MCCB, 32 A, 121 kA at 240

MPN3VA1032-4ED36-0KA0

Siemens SENTRON 3VA1032-4ED36-0KA0, molded case circuit breaker, 3-pole, 32 A rated continuous current, 121 kA interrupting at 240 V, TM210 overcurrent release, shunt trip, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1032-4ED36-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1032-4ED36-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C30.72 A
Current at 60 °C30.08 A
Current at 65 °C29.44 A
Current at 70 °C28.8 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1032-4ED36-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1032-4ED36-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-4ED36-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1032-4ED36-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-4ED36-0KA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1032-4ED36-0KA0 is a 3-pole molded case circuit breaker rated for 32 A continuous current and a 121 kA interrupting capacity at 240 V. The interrupting ratings step down to 75.6 kA at 415 V and 52.5 kA at 440 V, with 11.9 kA remaining at 690 V, so it handles high-fault service-entrance or distribution panels where the available fault current is substantial.

The breaker holds its full 32 A rating up to 50 °C ambient; above that it derates linearly to 28.8 A at 70 °C. In a sealed panel with minimal airflow, that derating curve governs the real load you can protect. The 70 mm depth and 76.2 mm width fit standard SENTRON 3VA panel cutouts, and the IP40 front protection keeps dust out of the enclosure face.

Frequently asked questions

Where can I buy 3VA1032-4ED36-0KA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the interrupting capacity of 3VA1032-4ED36-0KA0 at 240 V?

121 kA at 240 V, stepping down to 75.6 kA at 415 V and 52.5 kA at 440 V.

Does this MCCB include an undervoltage release or auxiliary contacts?

No. It ships with a shunt trip release only — no undervoltage release, no auxiliary contacts, and no communication function.

MPN
3VA1032-4ED36-0KA0