Skip to main content
Siemens 3VA1040-2ED32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1040-2ED32-0AC0 SENTRON MCCB, 40 A, 3-Pole, TM210

MPN3VA1040-2ED32-0AC0

Siemens SENTRON 3VA1040-2ED32-0AC0, molded case circuit breaker, 3-pole, 40 A rated continuous current Iu, TM210 thermal-magnetic overcurrent release, 2 auxiliary switches HQ, breaking capacity 52.5 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1040-2ED32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1040-2ED32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1040-2ED32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1040-2ED32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1040-2ED32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1040-2ED32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1040-2ED32-0AC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens 3VA1040-2ED32-0AC0 — SENTRON 40 A MCCB with TM210 Release

The Siemens 3VA1040-2ED32-0AC0 is a SENTRON molded case circuit breaker (MCCB) rated for 40 A continuous current (Iu) at 40 °C ambient, with a 3-pole configuration and a TM210 thermal-magnetic overcurrent release.

The interrupting ratings span the common industrial voltages: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. For a 480 V panel (common in North America), the 13.6 kA at 440 V figure is the closest published value — expect the actual 480 V rating to be slightly lower, so verify against the available fault current at the point of installation. The 690 V rating confirms it handles European 400/690 V distribution.

Above that, derating begins: 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C. For a panel that runs warm — say a sealed enclosure near a process line — the 70 °C figure is the ceiling; the breaker still delivers 36 A, which is 90% of its nameplate. Front IP40 protection means it's splash-resistant from the front but not sealed for washdown environments.

Physical Fit and Auxiliary Contacts

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint for DIN-rail or panel-mount integration. The auxiliary contact version is 2 auxiliary switches HQ (high-qualified), meaning two form-C (changeover) contacts rated for signal-level switching. No trip indicator is fitted, so fault diagnostics rely on the auxiliary contact state or a downstream indication circuit.

Frequently asked questions

Where can I buy 3VA1040-2ED32-0AC0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1040-2ED32-0AC0 at 415 V?

32 kA at 415 V, with ratings also published at 240 V (52.5 kA), 440 V (13.6 kA), and 690 V (7.5 kA).

Does 3VA1040-2ED32-0AC0 have an adjustable trip curve?

No. The TM210 release has a fixed thermal element at 40 A and a fixed magnetic pickup at 10× Iu (400 A). No adjustable response time or phase failure detection is fitted.

MPN
3VA1040-2ED32-0AC0