Skip to main content
Siemens 3VA1040-2ED32-0BA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1040-2ED32-0BA0 MCCB, 3-Pole, 40 A, TM210

MPN3VA1040-2ED32-0BA0

SENTRON 3VA1040-2ED32-0BA0, molded case circuit breaker, 3-pole, 40 A (40 °C), TM210 release, undervoltage release, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1040-2ED32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10402ED320AA0
3VA1040-2ED32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.13.3 W
3VA1040-2ED32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1040-2ED32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1040-2ED32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1040-2ED32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1040-2ED32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

At 55 °C it drops to 38.4 A, and at 70 °C it's 36 A. Breaking capacity is given at several voltages: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V.

Dimensions are 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or screw-mount panel layouts. The supplied basic switch is order code 3VA10402ED320AA0, which is the core switching mechanism; this variant adds the undervoltage release module on top. No communication function and no ground-fault monitoring version — this is a plain line-protection breaker with a UVR. If you need remote trip indication or ground-fault, you are looking at a different 3VA variant.

Frequently asked questions

Where can I buy 3VA1040-2ED32-0BA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the depth of 3VA1040-2ED32-0BA0?

The depth is 70 mm (2.76 in).

What is the width of 3VA1040-2ED32-0BA0?

The width is 76.2 mm (3 in).

Will 3VA1040-2ED32-0BA0 drop into a panel specified around 3VA1110-5EF32-0LA0?

No — the 3VA1110-5EF32-0LA0 is a 100 A frame with different dimensions and a different release (electronic, not TM210). The 3VA1040 is a 40 A frame; it will not physically or electrically replace a 100 A breaker without rewiring and re-coordination.

MPN
3VA1040-2ED32-0BA0