Siemens 3VA1040-2ED32-0HH0 SENTRON MCCB, 40 A, 52.5 kA

MPN3VA1040-2ED32-0HH0

Siemens SENTRON 3VA1040-2ED32-0HH0, molded case circuit breaker, 3-pole, 40 A rated continuous current Iu, 52.5 kA interrupting at 240 V, TM210 thermal-magnetic release, shunt trip STL, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1040-2ED32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1040-2ED32-0HH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1040-2ED32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1040-2ED32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1040-2ED32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1040-2ED32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1040-2ED32-0HH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The 40 A rating holds flat from 40 °C up to 50 °C, then derates to 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C. This is a 3-pole unit with a shunt trip release (STL) for remote opening and an auxiliary contact block configured as 2 auxiliary switches plus 1 trip alarm switch (HQ).

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep. Front protection is IP40.

Frequently asked questions

Does this MCCB include a shunt trip or undervoltage release?

It includes a shunt trip release (STL) for remote tripping. There is no undervoltage release, no ground-fault monitoring, and no phase-failure detection.

MPN