Skip to main content
Siemens 3VA1040-3ED36-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1040-3ED36-0JC0 SENTRON MCCB, 40 A, 3-Pole, Line

MPN3VA1040-3ED36-0JC0

Siemens SENTRON 3VA1040-3ED36-0JC0, molded case circuit breaker, 3-pole, 40 A, TM210 thermal-magnetic release, line protection, breaking capacity 75.6 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1040-3ED36-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1040-3ED36-0JC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA
3VA1040-3ED36-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1040-3ED36-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1040-3ED36-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1040-3ED36-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1040-3ED36-0JC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The TM210 thermal-magnetic release holds the full 40 A from 40 °C up through 50 °C; above that the curve steps down to 38.4 A at 55 °C and reaches 36 A at 70 °C. For a panel builder, that means the breaker can be packed into a warm enclosure without derating until the internal ambient exceeds 50 °C — a practical headroom for most standard switchgear builds.

The interrupting rating varies sharply with line voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. The 415 V figure (52.5 kA) is the one most often checked for European industrial panels — it comfortably exceeds typical 25–36 kA fault levels on a 400 V distribution bus.

At 130 mm high, 76.2 mm wide, and 70 mm deep, the 3VA1040-3ED36-0JC0 fits the standard 3-pole MCCB footprint for the SENTRON 3VA platform. The 76.2 mm width matches the typical 3-module DIN-rail or mounting-plate cutout.

Auxiliary and shunt trip configuration

The shunt trip order code for replacement is 3VA9688-0BL32.

Frequently asked questions

What is 3VA1040-3ED36-0JC0's listed depth?

The depth is 70 mm.

What is 3VA1040-3ED36-0JC0's listed width?

The width is 76.2 mm.

MPN
3VA1040-3ED36-0JC0