Siemens 3VA1040-4ED32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1040-4ED32-0AF0 SENTRON MCCB, 40 A, 3-Pole, 121 k

MPN3VA1040-4ED32-0AF0

Siemens SENTRON 3VA1040-4ED32-0AF0, molded case circuit breaker, 3-pole, 40 A rated current, TM210 thermal-magnetic release, line protection, 121 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1040-4ED32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10404ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1040-4ED32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C38.4 A
Current at 60 °C37.6 A
Current at 65 °C36.8 A
Current at 70 °C36 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.8 W

Protection & Trip Unit

3VA1040-4ED32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1040-4ED32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1040-4ED32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2

Environmental

3VA1040-4ED32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1040-4ED32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB delivers

The Siemens 3VA1040-4ED32-0AF0 is a SENTRON molded case circuit breaker built for line protection in distribution panels. Three poles, rated 40 A at 40 °C ambient, with a TM210 thermal-magnetic release — the thermal element handles overloads, the magnetic element clears short circuits. Breaking capacity hits 121 kA at 240 V and 75.6 kA at 415 V, so it handles high-fault utility feeds without cascading upstream.

Breaking capacity across voltages

This MCCB delivers 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. That spread covers most industrial supply voltages — the 415 V figure is what matters for a 400 V class panel in Europe or Asia; the 240 V figure suits North American 120/240 V services.

Thermal derating and enclosure fit

Rated 40 A from 40 °C to 50 °C ambient, then derates to 38.4 A at 55 °C, 37.6 A at 60 °C, 36.8 A at 65 °C, and 36 A at 70 °C. In a sealed panel running hot, you lose about 10 % of the rating. Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep — standard 3-pole MCCB footprint for DIN-rail or panel-mount integration.

Frequently asked questions

What is the breaking capacity of 3VA1040-4ED32-0AF0 at 415 V?

75.6 kA at 415 V, which is the key figure for 400 V class distribution panels.

What overcurrent release does this MCCB use?

TM210 thermal-magnetic release — thermal for overloads, magnetic for short circuits.

Where can I buy 3VA1040-4ED32-0AF0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
3VA1040-4ED32-0AF0