Siemens 3VA1050-2ED32-0AC0 MCCB, 50 A, 52.5 kA at 240 V

MPN3VA1050-2ED32-0AC0

Siemens SENTRON 3VA1050-2ED32-0AC0, molded case circuit breaker, 3-pole, 50 A rated continuous current, TM210 overcurrent release, 52.5 kA at 240 V, 32 kA at 415 V, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1050-2ED32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1050-2ED32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1050-2ED32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1050-2ED32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-2ED32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1050-2ED32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-2ED32-0AC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Integrator note — 3VA1050-2ED32-0AC0

The Siemens 3VA1050-2ED32-0AC0 is a 3-pole SENTRON molded case circuit breaker rated for 50 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release. Breaking capacity runs 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — so the SCCR headroom depends on your system voltage.

Thermal derating and current capacity

Above that it derates: 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. The TM210 release has a 1 s maximum adjustable time delay on the thermal element.

Panel fit and auxiliary contacts

Two HQ auxiliary switches are integrated; no separate aux kit needed. The IP40 front means it's fine in a closed cabinet but not washdown-rated.

Frequently asked questions

What are the key ratings for this MCCB?

Rated continuous current is 50 A (flat to 50 °C, then derating to 45 A at 70 °C). Breaking capacity: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, 7.5 kA at 690 V. Insulation voltage is 800 V.

Where can I buy 3VA1050-2ED32-0AC0 and how is it quoted?

This part is sourced through independent distribution channels. Submit an RFQ for current pricing and availability — quotes are confirmed at order time, not listed here.

What is the physical size of this breaker?

Depth is 70 mm, width is 76.2 mm, height is 130 mm. Fits standard SENTRON panel cutouts.

Does this breaker include auxiliary contacts?

Yes, it comes with two HQ auxiliary switches integrated. No separate aux contact module needed.