Siemens 3VA1050-2ED32-0HH0 Circuit Breaker, 50A, 16kA @ 415V

MPN3VA1050-2ED32-0HH0

Siemens 3VA1 IEC frame 100, 3-pole, 50A, breaking capacity class B Icu=16kA @ 415V, TM210 thermal-magnetic trip, shunt trip STL 12-30V DC / 24V AC, 2 HQ aux switches + 1 HQ trip alarm switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1050-2ED32-0HH0 is a 3-pole IEC frame 100 circuit breaker rated 50 A with a class B breaking capacity of 16 kA at 415 V. That class B rating means it handles moderate fault levels typical of distribution sub-feeders — enough headroom for selective coordination with downstream 10 kA branch breakers, but not the 25+ kA class C needed at a main service entrance. The TM210 thermal-magnetic trip unit is factory-fixed: overload protection Ir is set at 50 A (non-adjustable), and short-circuit protection Ii is fixed at 10 × In (500 A). No field dials to mis-set — good for a BOM line where the engineer wants repeatable coordination without commissioning tweaks.

Integrated accessories — what ships on the breaker

This variant comes pre-populated with a shunt trip (STL) rated 12–30 V DC or 24 V AC 50/60 Hz, plus two HQ auxiliary switches and one HQ trip alarm switch. That means the panel builder does not need to order and install separate accessory packs — the shunt trip is wired for remote tripping (fire alarm, E-stop chain), and the aux contacts report breaker position to a PLC or status lamp. The HQ designation indicates high-auxiliary-current rating for the switch contacts, suitable for control circuits up to the standard 6 A AC-15 / 3 A DC-13 range. A nut keeper kit is also included in the package for secure DIN-rail mounting.

Where it fits — panel and coordination context

The 3VA1 frame 100 mounts on standard DIN rail in an IEC distribution panel or enclosure. At 50 A fixed, it is sized for a motor control center feeder, a lighting sub-panel, or a small UPS bypass circuit. The 16 kA Icu at 415 V coordinates cleanly with a 25 kA upstream main breaker (typical class C) if the let-through energy is within the downstream breaker's I2t withstand. For North American installations, verify that the 415 V rating aligns with your 480Y/277 V system — the breaker is IEC-rated, not UL489 listed, so it is suited for IEC-spec panels and export projects.

Frequently asked questions

What is the breaking capacity of this breaker?

Breaking capacity class B with Icu = 16 kA at 415 V AC, which is the maximum short-circuit current the breaker can safely interrupt at that voltage.

What accessories are included on this variant?

It ships with a shunt trip (STL) rated 12-30 V DC / 24 V AC, two HQ auxiliary switches, one HQ trip alarm switch, and a nut keeper kit for DIN-rail mounting.

Where can I buy 3VA1050-2ED32-0HH0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume.