Siemens 3VA1050-2ED32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-2ED32-0JC0 SENTRON MCCB, 50 A, 3-Pole

MPN3VA1050-2ED32-0JC0

Siemens SENTRON 3VA1050-2ED32-0JC0, molded case circuit breaker, 3-pole, 50 A (40 °C), line protection, with shunt trip (STL) and 2 auxiliary switches (HQ), breaking capacity 52.5 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-2ED32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10502ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1050-2ED32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W
3VA1050-2ED32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-2ED32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-2ED32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1050-2ED32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-2ED32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It holds that 50 A rating flat through 50 °C, then derates to 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C — useful to know if the breaker sits near other heat sources in a sealed enclosure. Breaking capacity steps from 52.5 kA at 240 V down to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V. That 52.5 kA at 240 V covers high-fault utility secondaries; the 7.5 kA at 690 V still clears industrial motor-feed faults. The two auxiliary switches report open/closed status back to a control system or status panel.

Dimensions are 76.2 mm wide, 130 mm high, 70 mm deep — a standard 3-pole MCCB footprint that fits most Siemens SENTRON distribution panels and third-party enclosures with the appropriate mounting base. No undervoltage release is fitted; if undervoltage protection is needed, that release must be added separately.

Frequently asked questions

What is the breaking capacity of 3VA1050-2ED32-0JC0 at different voltages?

Breaking capacity is 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

What auxiliary releases and switches come with this MCCB?

It includes a shunt trip (STL) release for remote tripping and two HQ auxiliary switches for status feedback.

Where can I buy 3VA1050-2ED32-0JC0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN