Skip to main content
Siemens 3VA1050-2ED32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-2ED32-0KA0 SENTRON MCCB, 50 A, 52.5 kA at 24

MPN3VA1050-2ED32-0KA0

Siemens SENTRON 3VA1050-2ED32-0KA0, molded case circuit breaker, 3-pole, 50 A, TM210 release, shunt trip, 52.5 kA at 240 V, 70 mm depth, 76.2 mm width, 130 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-2ED32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10502ED320AA0
3VA1050-2ED32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W
3VA1050-2ED32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-2ED32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-2ED32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-2ED32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-2ED32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1050-2ED32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated 50 A continuous at 40 °C, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) auxiliary release.

Rated breaking capacity reaches 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

Maximum power loss is 14.6 W — relevant for enclosure thermal calculations when grouping multiple breakers.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint that fits most DIN-rail or screw-mount panel layouts. The shunt trip (STL) adds a small module on the side; verify clearance if retrofitting into a tight gland plate.

Frequently asked questions

Where can I buy 3VA1050-2ED32-0KA0 and how is it quoted for volume?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest functional second-source — 3VA1010-2ED32-0AD0?

The 3VA1010-2ED32-0AD0 is a lower-current sibling (10 A frame) with the same TM210 release and shunt trip, so it shares the same footprint and wiring pattern. It will drop into a panel specified for the 3VA1050 without rewiring, but the continuous rating must match the load — the 50 A 3VA1050 cannot be replaced by a 10 A breaker.

What is the depth of 3VA1050-2ED32-0KA0?

The depth is 70 mm (2.76 in).

What is the width of 3VA1050-2ED32-0KA0?

The width is 76.2 mm (3 in).

Will 3VA1050-2ED32-0KA0 drop into a panel that was specified around 3VA1010-2ED32-0AD0 without rewiring?

Yes — both share the same 3-pole footprint, same TM210 release, and same shunt trip module, so the physical fit and terminal layout are identical. The only difference is the continuous current rating (50 A vs 10 A), so the upstream protection and conductor sizing must be verified.

What compliance documentation does Siemens provide for 3VA1050-2ED32-0KA0?

Siemens SENTRON MCCBs typically carry UL 489, CSA C22.2 No. 5, IEC 60947-2, CE, and RoHS/REACH declarations. Specific certs for this order code should be confirmed at quote time, as the evidence does not list them individually.

MPN
3VA1050-2ED32-0KA0