Siemens 3VA1050-2ED36-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-2ED36-0AF0 SENTRON MCCB, 50 A, 3-Pole, Line

MPN3VA1050-2ED36-0AF0

Siemens SENTRON 3VA1050-2ED36-0AF0, molded case circuit breaker, 3-pole, 50 A rated continuous current Iu, TM210 thermal-magnetic overcurrent release, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-2ED36-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1050-2ED36-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1050-2ED36-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1050-2ED36-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-2ED36-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1050-2ED36-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-2ED36-0AF0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The 3VA1050-2ED36-0AF0: This breaker's interrupting capacity changes with system voltage, which is typical for MCCBs but easy to miss when you're pulling a BOM from a one-line. At 240 V it clears 52.5 kA; at 415 V it clears 32 kA; at 440 V it clears 13.6 kA; and at 690 V it clears 7.5 kA.

Thermal derating — the real-world current you can actually run

Above that, it starts to taper: 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C.

Footprint and panel integration

That width is three standard 25.4 mm pole spacings, so it fits a typical 3-pole MCCB cutout in a distribution panel without surprises.

Frequently asked questions

Where can I buy the 3VA1050-2ED36-0AF0?

This breaker is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for this MCCB?

Siemens provides RoHS, REACH, UL, and IEC declarations for the SENTRON 3VA series through their standard support documentation.

MPN
3VA1050-2ED36-0AF0