Siemens 3VA1050-2ED36-0AH0 SENTRON MCCB, 50A, 52.5kA at 240V

MPN3VA1050-2ED36-0AH0

Siemens SENTRON 3VA1050-2ED36-0AH0, 3-pole molded case circuit breaker, Line protection, 50 A rated continuous current Iu, TM210 overcurrent release, breaking capacity 52.5 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-2ED36-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1050-2ED36-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1050-2ED36-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1050-2ED36-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-2ED36-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1050-2ED36-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-2ED36-0AH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

SENTRON 3VA1050-2ED36-0AH0 — 50 A MCCB with TM210 release

Breaking capacity is specified across four voltage levels: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. The breaker holds full 50 A up to 50 °C, then drops to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C.

Panel fit and auxiliary contacts

That gives two form-C signals for status feedback and a separate alarm contact that changes state only on a trip event — useful for remote annunciation without wiring through the breaker handle position. Front protection is IP40, adequate for clean indoor panel environments.

Frequently asked questions

Does this breaker include a shunt trip or undervoltage release?

No. The 3VA1050-2ED36-0AH0 ships without any auxiliary release — no undervoltage release, no shunt trip, no ground-fault monitoring. It is a plain thermal-magnetic line-protection breaker with the HQ auxiliary contact block (2 aux + 1 alarm).

MPN