Siemens 3VA1050-2ED36-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-2ED36-0CC0 SENTRON MCCB, 50 A, 52.5 kA

MPN3VA1050-2ED36-0CC0

Siemens SENTRON 3VA1050-2ED36-0CC0, 3-pole molded case circuit breaker, 50 A rated continuous current, TM210 thermal-magnetic release, 52.5 kA at 240 V, undervoltage release, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1050-2ED36-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1050-2ED36-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1050-2ED36-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1050-2ED36-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1050-2ED36-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2

Environmental

3VA1050-2ED36-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1050-2ED36-0CC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Integrator's note on the 3VA1050-2ED36-0CC0

The 50 A rating holds flat from 40 °C to 50 °C, then derates to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. If the panel ambient runs above 50 °C, the continuous current drops — size your load accordingly. The insulation voltage (Ui) is 800 V, which covers most industrial distribution voltages including 690 V systems.

Panel fit and auxiliary wiring

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep. The 76.2 mm width is a standard 3-pole MCCB footprint for this SENTRON generation — it fits existing panel cutouts and busbar spacing designed for 3VA or earlier 3VL frames. Front IP40 protection means it's fine inside a closed panel; no washdown rating on the front face. Factory-fitted with 2 auxiliary switches (HQ type) and an undervoltage release (UVR). The auxiliary switches give you two independent signal paths for status feedback to a PLC or indication lamp. The UVR drops the breaker when control voltage falls below the dropout threshold — common in emergency-stop circuits or undervoltage protection schemes. The integrated auxiliary trip is order code 3VA9608-0BB24; if that specific trip unit is needed, note it separately on the BOM.

What the TM210 release means for coordination

The TM210 is a thermal-magnetic release with fixed settings. The 15,000 latching endurance cycles give a baseline for mechanical life.

Frequently asked questions

What auxiliary options come factory-fitted on this breaker?

It ships with 2 HQ-type auxiliary switches and an undervoltage release (UVR). The auxiliary switches provide two independent status signals; the UVR trips the breaker on loss of control voltage.

MPN
3VA1050-2ED36-0CC0