Skip to main content
Siemens 3VA1050-3ED32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-3ED32-0JA0 SENTRON MCCB, 50 A, 3-Pole, TM210

MPN3VA1050-3ED32-0JA0

Siemens SENTRON 3VA1050-3ED32-0JA0, molded case circuit breaker, 3-pole, 50 A, TM210 thermal-magnetic release, line protection, shunt trip, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-3ED32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1050-3ED32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA
3VA1050-3ED32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1050-3ED32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-3ED32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-3ED32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-3ED32-0JA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1050-3ED32-0JA0 is a 3-pole SENTRON molded case circuit breaker rated for 50 A continuous current (Iu) at 40 °C, with the TM210 thermal-magnetic overcurrent release handling the protection curve. That 50 A holds steady through 50 °C; above that it derates to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C — so if your panel ambient runs hot, size the load side accordingly. Breaking capacity lands at 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V — that's enough headroom for most industrial distribution panels on 400 V class systems, but the 690 V figure means you need to check coordination if feeding a 690 V drive input.

The 3VA1050-3ED32-0JA0 measures 70 mm deep, 76.2 mm wide, and 130 mm tall — a standard 3-pole MCCB footprint that drops into a SENTRON distribution board or a separate enclosure with DIN-rail adapter.

Frequently asked questions

Does this breaker include a shunt trip or undervoltage release?

It includes a shunt trip (STL) auxiliary release. It does not include an undervoltage release, auxiliary contacts, or ground-fault monitoring.

MPN
3VA1050-3ED32-0JA0