Siemens 3VA1050-3ED32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-3ED32-0JA0 SENTRON MCCB, 50 A, 3-Pole, TM210

MPN3VA1050-3ED32-0JA0

Siemens SENTRON 3VA1050-3ED32-0JA0, molded case circuit breaker, 3-pole, 50 A, TM210 thermal-magnetic release, line protection, shunt trip, 70 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1050-3ED32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1050-3ED32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1050-3ED32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1050-3ED32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1050-3ED32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1050-3ED32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1050-3ED32-0JA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this MCCB carries — and what it doesn't

The Siemens 3VA1050-3ED32-0JA0 is a 3-pole SENTRON molded case circuit breaker rated for 50 A continuous current (Iu) at 40 °C, with the TM210 thermal-magnetic overcurrent release handling the protection curve. That 50 A holds steady through 50 °C; above that it derates to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C — so if your panel ambient runs hot, size the load side accordingly. Breaking capacity lands at 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V — that's enough headroom for most industrial distribution panels on 400 V class systems, but the 690 V figure means you need to check coordination if feeding a 690 V drive input. This version ships with a shunt trip (STL) auxiliary release but no undervoltage release, no auxiliary contacts, no ground-fault monitoring, and no communication module.

Panel fit and wiring

The 3VA1050-3ED32-0JA0 measures 70 mm deep, 76.2 mm wide, and 130 mm tall — a standard 3-pole MCCB footprint that drops into a SENTRON distribution board or a separate enclosure with DIN-rail adapter. Front protection is IP40, so it's fine inside a closed panel but not for washdown zones. Rated insulation voltage is 800 V. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Frequently asked questions

Does this breaker include a shunt trip or undervoltage release?

It includes a shunt trip (STL) auxiliary release. It does not include an undervoltage release, auxiliary contacts, or ground-fault monitoring.