Siemens 3VA1050-3ED36-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-3ED36-0DH0 SENTRON MCCB, 50 A, 3-Pole, 75.6

MPN3VA1050-3ED36-0DH0

Siemens SENTRON 3VA1050-3ED36-0DH0, molded case circuit breaker, 3-pole, 50 A rated, breaking capacity 75.6 kA at 240 V, line protection, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-3ED36-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10503ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1050-3ED36-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.1 W
3VA1050-3ED36-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-3ED36-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-3ED36-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1050-3ED36-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-3ED36-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1050-3ED36-0DH0 is a 3-pole molded case circuit breaker (MCCB) rated 50 A at 40 °C, designed for line protection in distribution panels. Its breaking capacity reaches 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V, tapering to 7.5 kA at 500 V and 690 V — figures that govern selectivity coordination downstream.

The 70 mm depth and 76.2 mm width fit a 3-pole MCCB footprint common in SENTRON distribution boards.

Frequently asked questions

What is the breaking capacity of 3VA1050-3ED36-0DH0 at 415 V?

At 415 V the breaking capacity is 52.5 kA. At 240 V it is 75.6 kA, and at 440 V it is 32 kA.

What auxiliary switches and releases come with this breaker?

It includes an undervoltage release (UVR) and is fitted with 2 auxiliary switches plus 1 trip alarm switch (HQ).

Where can I buy 3VA1050-3ED36-0DH0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1050-3ED36-0DH0