Specifications

3VA1050-3ED36-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10503ED360AA0
3VA1050-3ED36-0HA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W
3VA1050-3ED36-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-3ED36-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-3ED36-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-3ED36-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-3ED36-0HA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1050-3ED36-0HA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 50 A continuously at 40 °C through 50 °C ambient, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL). Breaking capacity is voltage-dependent: 75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V — giving the SCCR headroom for most industrial distribution panels fed from a transformer secondary up to 690 V.

Above that, current must be reduced: 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. The storage limit governs handling during transport and warehouse hold, not running duty.

The 3VA1050-3ED36-0HA0 measures 130 mm high, 76.2 mm wide, and 70 mm deep. The 76.2 mm width (3 inches) is the standard 3-pole MCCB footprint for this SENTRON generation — it occupies the same DIN-rail or mounting-plate slot as other 3VA frame breakers.

Frequently asked questions

Where can I buy 3VA1050-3ED36-0HA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability — no stock or price figures are published here.

What is 3VA1050-3ED36-0HA0's breaking capacity at different voltages?

Breaking capacity is 75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

MPN
3VA1050-3ED36-0HA0