Skip to main content
Siemens 3VA1050-3ED36-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-3ED36-0KC0 SENTRON MCCB, 50 A, 75.6 kA

MPN3VA1050-3ED36-0KC0

Siemens SENTRON 3VA1050-3ED36-0KC0, molded case circuit breaker, 3-pole, 50 A at 40 °C, interrupting 75.6 kA at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-3ED36-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10503ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1050-3ED36-0KC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W
3VA1050-3ED36-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-3ED36-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-3ED36-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1050-3ED36-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-3ED36-0KC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Thermal derating and power dissipation

At 55 °C it derates to 49 A, at 60 °C to 48 A, at 65 °C to 46 A, and at 70 °C to 45 A.

Width 76.2 mm (3 in), height 130 mm (5.12 in), depth 70 mm (2.76 in). That's the standard SENTRON 3VA1 footprint — fits the same DIN-rail or panel-mount cutout as other 3VA frame sizes. No trip indicator on this variant; undervoltage release is not fitted. Auxiliary switch design is 2 HQ auxiliary switches, and a shunt trip (STL) is included as the auxiliary release.

Frequently asked questions

Where can I buy 3VA1050-3ED36-0KC0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the interrupting capacity of 3VA1050-3ED36-0KC0?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

Does 3VA1050-3ED36-0KC0 drop into a panel specified for 3VA1110-5ED36-0AC0?

Both are SENTRON 3VA1 frame sizes, so the 76.2 mm width and 130 mm height are identical. The 3VA1050 is a 50 A line-protection breaker; the 3VA1110 is a 100 A breaker. Panel cutout and busbar spacing are the same, but the ampacity difference means you cannot swap them without checking the downstream load and upstream coordination.

MPN
3VA1050-3ED36-0KC0