Skip to main content
Siemens 3VA1050-4ED36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-4ED36-0AA0 SENTRON MCCB, 50 A, 3-Pole, 121 k

MPN3VA1050-4ED36-0AA0
Active

Siemens SENTRON 3VA1050-4ED36-0AA0, molded case circuit breaker, 3-pole, 50 A rated, TM210 thermal-magnetic release, line protection version, breaking capacity 121 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-4ED36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1050-4ED36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.14.6 W
3VA1050-4ED36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1050-4ED36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-4ED36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-4ED36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-4ED36-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1050-4ED36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 50 A continuous current at 40 °C, with a TM210 thermal-magnetic release that is non-adjustable for the I²t trip characteristic. It is configured as a line protection device — meaning it is intended for cable and busbar protection in distribution panels, not motor branch circuits where adjustable overloads are needed. Breaking capacity is the headline decision point here: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. Thermal derating is published: the breaker holds 50 A from 40 °C through 50 °C, then drops to 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C.

The 3-pole width of 76.2 mm (3 inches) is the standard MCCB footprint for this current class. No IP rating on the sides or rear; the breaker relies on the enclosure for overall panel seal. If you need remote trip indication or shunt trip, you add the accessory later; the 3VA platform supports plug-in auxiliaries.

Delta: How It Sits Against a Sibling

Compared to the 3VA1110-5MH36-0AA0 — which is also a 3-pole SENTRON but with an electronic release (ETU) and higher current rating — the 3VA1050-4ED36-0AA0 uses a fixed TM210 thermal-magnetic release. The TM210 is simpler, cheaper, and non-adjustable; the ETU version offers adjustable I²t curves and ground-fault options.

Frequently asked questions

Will 3VA1050-4ED36-0AA0 drop into a panel specified for 3VA1110-5MH36-0AA0?

Yes, the width is identical at 76.2 mm (3 inches), so the mounting footprint and busbar spacing are the same. The 3VA1050 uses a fixed TM210 thermal-magnetic release versus the electronic release on the 3VA1110, so no wiring changes are needed for the breaker itself.

MPN
3VA1050-4ED36-0AA0